- <h2>Agilent 33XXX Series Instrument Driver Readme</h2>
- <para>To rate this driver, go to the driver download page on the <a
- href="http://www.ni.com/idnet">Instrument Driver Network</a>.</para>
- <h4>1. Overview</h4>
- <para>
- Instrument Driver Technology: LabVIEW Plug and Play (project-style)
- <br>
- Manufacturer: Agilent Technologies
- <br>
- Supported Language(s): LabVIEW
- <br>
- Supported Model(s): 33120A, 33220A, 33250A, 33210A
- <br>
- Model(s) Tested: 33120A, 33220A, 33250A, 33210A
- <br>
- Interface(s): GPIB
- <br>
- Firmware Revision Tested: 7.0-2.0-1.0
- <br>
- <br>
- Certified: Yes
- <br>
- NI Supported: Yes
- <br>
- Source Code Available: Yes
- <br>
- <br>
- Driver Revision: 2.1.4
- <br>
- Original Release Date: 07/06/2005
- <br>
- Current Revision Date: 08/12/2013
- </para>
- <h4>2. Required Software</h4>
- <para>Some software components need to be installed before using this
- instrument driver. The minimum versions of these components are listed
- below, and can be downloaded from the Download Site.
- <br>
- <br>
- VISA 3.0 or later
- <br>
- <br>
- <br>
- For more details, refer to the <i>LabVIEW Help</i> under <i>Help
- » VI, Function, & How-To Help</i>.</para>
- <h4>3. Known Issues</h4>
- <para>
- A delay has been included in Create Arbitrary Waveform in order to prevent Query Interrupted (-410) instrument error from
- occurring. The error occurs when error query is called from Create Arbitrary Waveform when a small transfer
- (8-16 points) is sent over ther serial interface.
- <br>
- <br>
- A delay occurs on the instrument after writing multiple arbitrary waveforms to a 33220A. The instrument has a limited amount of flash memory, and
- eventually must clean up the memory, this is when the delay occurs.
- </para>
- <para><br><br>
- To report issues or provide feedback about this instrument driver,
- please send an email to <a href="mailto:instrument.drivers@ni.com">instrument.drivers@ni.com</a>.</para></font><font
- face="Times New Roman" size="3">
- <br>
- <font face="Times New Roman" size="3"><para></para>
- <h4>4. Revision History</h4>
- <para>The latest version of this and other LabVIEW and LabWindows/CVI
- instrument drivers can be downloaded at the <a
- href="http://www.ni.com/idnet">Instrument Driver Network</a>.<br>
- <br>
- Revision 2.0, 07/6/2005
- <br>
- Modified by: Matt Gibson, Rob Hammond, Austin, TX.
- <br>
- Original release for LabVIEW 8.0 created from ag33xxx driver (v.1.0.1) in LV 7.0
- <br><br>
- Revision 2.0.1, 10/4/2006
- <br>
- Modified by Sandy Hermanwan, Austin, TX.
- <br>
- Documentation updates.
- <br><br>
- Revision 2.0.2, 01/21/2008
- <br>
- Modified by Berk Ozdogan, Austin, TX.
- <br>
- Configure Trigger VI is modified so that trigger delay is only passed in for 33250 models. Overall implementation of the VI is
- also revised to better comply with instrument driver standards.
- <br><br>
- Revision 2.1.0, 10/31/2008
- <br>
- Modified by Fan Chen, Shanghai, China.
- <br>
- Add support for Agilent 33210 model. Update the driver template.
- Add Configure Burst.vi to support 33210 model's burst function.
- <br><br>
- Revision 2.1.1, 1/26/2009
- <br>
- Modified by Nathan T., Austin, Texas.
- <br>
- Changed the format specifier in Configure Standard Waveform.vi Frequency Command string constant from "%g" to "%f" to correct a problem with frequency rounding.
- <br><br>
- Revision 2.1.2, 3/10/2010
- <br>
- Modified by Nathan T., Austin, Texas.
- <br>
- Fixed the scaling calculation in Scale Arbitrary Waveform.vi by negating the max value and using that for the calculations instead of the min value.
- <br><br>
- Revision 2.1.3, 9/24/2012<br>
- Modified by JP (NI), Wim T. (Phillps)<br>
- Modified Scale Arbitrary Waveform.vi to use real min instead of using inverted max value.
- <br><br>
- Revision 2.1.4, 8/12/2013
- <br>
- Modified by Stephen Schwahn, Austin, Texas.
- <br>
- Added the "BURS:STAT OFF" command in the Configure Burst VI to allow the burst to be disabled.