  1. <!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
  2. <html>
  3. <head>
  4. <title>Instrument Driver Readme</title>
  5. </head>
  6. <body>
  7. <font face="Times New Roman" size="3">
  8. <h2>Agilent 33XXX Series Instrument Driver Readme</h2>
  9. <para>To rate this driver, go to the driver download page on the <a
  10. href="http://www.ni.com/idnet">Instrument Driver Network</a>.</para>
  11. <h4>1. Overview</h4>
  12. <para>
  13. Instrument Driver Technology: LabVIEW Plug and Play (project-style)
  14. <br>
  15. Manufacturer: Agilent Technologies
  16. <br>
  17. Supported Language(s): LabVIEW
  18. <br>
  19. Supported Model(s): 33120A, 33220A, 33250A, 33210A
  20. <br>
  21. Model(s) Tested: 33120A, 33220A, 33250A, 33210A
  22. <br>
  23. Interface(s): GPIB
  24. <br>
  25. Firmware Revision Tested: 7.0-2.0-1.0
  26. <br>
  27. <br>
  28. Certified: Yes
  29. <br>
  30. NI Supported: Yes
  31. <br>
  32. Source Code Available: Yes
  33. <br>
  34. <br>
  35. Driver Revision: 2.1.4
  36. <br>
  37. Original Release Date: 07/06/2005
  38. <br>
  39. Current Revision Date: 08/12/2013
  40. </para>
  41. <h4>2. Required Software</h4>
  42. <para>Some software components need to be installed before using this
  43. instrument driver. The minimum versions of these components are listed
  44. below, and can be downloaded from the Download Site.
  45. <br>
  46. <br>
  47. VISA 3.0 or later
  48. <br>
  49. <br>
  50. <br>
  51. For more details, refer to the <i>LabVIEW Help</i> under <i>Help
  52. &raquo; VI, Function, &amp; How-To Help</i>.</para>
  53. <h4>3. Known Issues</h4>
  54. <para>
  55. A delay has been included in Create Arbitrary Waveform in order to prevent Query Interrupted (-410) instrument error from
  56. occurring. The error occurs when error query is called from Create Arbitrary Waveform when a small transfer
  57. (8-16 points) is sent over ther serial interface.
  58. <br>
  59. <br>
  60. A delay occurs on the instrument after writing multiple arbitrary waveforms to a 33220A. The instrument has a limited amount of flash memory, and
  61. eventually must clean up the memory, this is when the delay occurs.
  62. </para>
  63. <para><br><br>
  64. To report issues or provide feedback about this instrument driver,
  65. please send an email to <a href="mailto:instrument.drivers@ni.com">instrument.drivers@ni.com</a>.</para></font><font
  66. face="Times New Roman" size="3">
  67. <br>
  68. <font face="Times New Roman" size="3"><para></para>
  69. <h4>4. Revision History</h4>
  70. <para>The latest version of this and other LabVIEW and LabWindows/CVI
  71. instrument drivers can be downloaded at the <a
  72. href="http://www.ni.com/idnet">Instrument Driver Network</a>.<br>
  73. <br>
  74. Revision 2.0, 07/6/2005
  75. <br>
  76. Modified by: Matt Gibson, Rob Hammond, Austin, TX.
  77. <br>
  78. Original release for LabVIEW 8.0 created from ag33xxx driver (v.1.0.1) in LV 7.0
  79. <br><br>
  80. Revision 2.0.1, 10/4/2006
  81. <br>
  82. Modified by Sandy Hermanwan, Austin, TX.
  83. <br>
  84. Documentation updates.
  85. <br><br>
  86. Revision 2.0.2, 01/21/2008
  87. <br>
  88. Modified by Berk Ozdogan, Austin, TX.
  89. <br>
  90. Configure Trigger VI is modified so that trigger delay is only passed in for 33250 models. Overall implementation of the VI is
  91. also revised to better comply with instrument driver standards.
  92. <br><br>
  93. Revision 2.1.0, 10/31/2008
  94. <br>
  95. Modified by Fan Chen, Shanghai, China.
  96. <br>
  97. Add support for Agilent 33210 model. Update the driver template.
  98. Add Configure Burst.vi to support 33210 model's burst function.
  99. <br><br>
  100. Revision 2.1.1, 1/26/2009
  101. <br>
  102. Modified by Nathan T., Austin, Texas.
  103. <br>
  104. Changed the format specifier in Configure Standard Waveform.vi Frequency Command string constant from "%g" to "%f" to correct a problem with frequency rounding.
  105. <br><br>
  106. Revision 2.1.2, 3/10/2010
  107. <br>
  108. Modified by Nathan T., Austin, Texas.
  109. <br>
  110. Fixed the scaling calculation in Scale Arbitrary Waveform.vi by negating the max value and using that for the calculations instead of the min value.
  111. <br><br>
  112. Revision 2.1.3, 9/24/2012<br>
  113. Modified by JP (NI), Wim T. (Phillps)<br>
  114. Modified Scale Arbitrary Waveform.vi to use real min instead of using inverted max value.
  115. <br><br>
  116. Revision 2.1.4, 8/12/2013
  117. <br>
  118. Modified by Stephen Schwahn, Austin, Texas.
  119. <br>
  120. Added the "BURS:STAT OFF" command in the Configure Burst VI to allow the burst to be disabled.
  121. </font></para></font>
  122. </body>
  123. </html>